Features
- Includes 151 dwg files of details, schedules, notes and symbols.
- The most complete set of CAD fire protection details on the market .
- Fully editable dwg files.
Fire - Design and analyze fire sprinkler systems.
S-Pipe - Design and analyze domestic supply water piping systems.
D-Pipe - Design and analyze drainage water piping systems.
Plumbing CAD Details - Expand your CAD drawing library and save hours of drawing time.
The consistent quality of your details sheets, job after job, can speak volumes about who you are as an engineer. Our Fire Protection CAD Details package can help broaden the foundation from which you assemble your design drawings, and give you the edge that will set you apart from your competitors.
Fire Protection Details are the most complete set of CAD fire protection details available on the market today. Unlike other CAD packages which have only details, Fire Protection Details includes standardized schedules, notes and symbols. Therefore, with this set of details, the fire protection engineer has a strong foundation from which to assemble his design drawings. These ready-to-use fire protection CAD details are an excellent addition to your CAD drawings library and will save you many hours in drawing time.
Our Fire Protection CAD Detail files are .dwg files and are fully editable - they are also supported by most CAD programs on the market today. Fire Protection CAD Details is only $350.
Fire Protection Details are not intended to be the sole source of information relied upon for the design of fire sprinkler systems, but an aid. In preparing design drawings, the engineer's judgment and experience should be the basis on which all decisions are made.
Alarm check valve detail |
Dry valve detail |
Dry pipe assembly detail |
Fire department connection detail |
Incoming fire service elevation |
Typical floor control valve detail |
Single interlocked preaction sprinkler system |
Wet and dry valve detail |
Hydraulic system sign detail |
Detail - wet alarm valve and trimmings |
New sprinkler system riser addition to existing |
Limited area sprinkler system riser detail |
Fire/domestic water riser diagram - limited area sprinkler system |
Fire pump piping schematic |
Wet pipe system riser detail |
Preaction alarm valve detail |
Sprinkler system riser diagram - two alarm check valves |
Sprinkler system riser diagram - dry valve and two alarm check valves |
Sprinkler system riser diagram - two dry valves |
Sprinkler system riser diagram - three alarm check valves |
Sprinkler system riser diagram - three dry valves |
Detail of antifreeze loop |
Detail of antifreeze loop |
Sprinkler system riser diagram - one alarm check valve |
Sprinkler system riser diagram - alarm check valve & hose rack riser |
Sprinkler system riser diagram -alarm check valve & dry valve |
Sprinkler system riser diagram - dry valve |
Sprinkler system riser diagram - dry valve and hose rack riser |
Floor control valve detail |
Floor control valve with fire dept. Valve detail |
Hydraulic - system sign detail |
Sprinkler system riser diagram - wet and dry valve |
Sprinkler system riser diagram - wet and dry valve |
Dry valve detail from wet supply main |
Hydraulic design information sign |
Fire department connection |
Fire hose station detail |
Deluge system |
Identification sign |
Typical fire pump controller and transfer switch arrangements |
Typical power supply arrangements from source to motor |
Typical foam pump piping details |
Vertical fire pump detail - below grade discharge arrangement |
Vertical shaft turbine-type pump installation in well |
Vertical shaft turbine-type pump installation in a wet pit |
Horizontal split-case fire pump installation with water supply under a positive head |
Connection for domestic water detail |
Fire department yard connection to a system with one or multiple risers |
Fire department connection to a dry-pipe sprinkler system having a single riser |
Alternate fire department connections to systems having two or more risers |
|
| Wall bracket pipe hanger detail | Beam pipe hanger | Standard c-clamp pipe hanger |
| "u" type pipe hanger | Clip pipe hanger | Pipe riser clamp detail |
| Stud type pipe hanger | Lag end pipe hanger | Concrete pipe hanger |
| Eye rod pipe hanger | Dry sprinkler auxiliary drain detail | Incoming water supply support detail |
| Typical sprinkler head relocation | Seismic restraint components (typical Applications) | Inspector's test connection |
| Sprinkler head detail | Typical sprinkler head relocation | Waterflow indicator assembly detail |
| Sprinkler head installation detail | Dry sprinkler system - typical attic and upper floor head relocation | Detail of sprinkler branch piping modification |
| System test connection detail | Dry inspector's test connection | Sprinkler head in laundry chute detail |
| Pipe riser support detail | Pipe sleeve through floor detail | Exterior wall sleeve detail |
| Pipe sleeve through wall detail | Curb box detail | Pipe support and seismic restraint detail - horizontal piping |
| Pipe support with seismic restraint detail | Thrust block detail | Pipe trench detail |
| Typical sprinkler relocation for temporary protection of open ceiling construction period | Placement of sidewall sprinkler adjacent to an end wall | Installation of sidewall sprinkler along a soffit |
| Detail of dry sprinklers protecting platforms and loading docks | Drain connection for system riser | Acceptable hangers for end of line pendent sprinklers |
| Bearing thrust block detail | ravity thrust block detail | Typical connection to a fire protection system riser |
| Refrigerator area sprinkler system detail | Multipurpose piping system schematic - preferable arrangement | Multipurpose piping system schematic - acceptable arrangement with valve supervision |
| Dual fire pump water supply detail | Water supply with fire pump backup detail | Sprinkler on riser nipple from branch line in lower fire area |
| Arrangements of branch lines supplying sprinklers above, in between, and below ceilings | Antifreeze solution arrangement of supply piping and valves | Typical city water pit - valve arrangement |
| Hydrant detail | Piping arrangement of air exhaust valves for combined dry pipe & preaction sprinkler system | Seismic bracing - riser details |
| Seismic bracing - short riser detail | Water supply connection with test connection detail | Acceptable types of sway bracing |
| Air supply to dry pipe valve from shop air system detail | Piping connection for pressure - sensing line detail | Piping connection detail for each automatic pressure switch (for fire pump and jockey pump) |
| Detail of four-way brace at riser | Drain connection for sprinkler riser |
Rooftop packaged heat pump unit schedule |
Rooftop air conditioning unit schedule |
Rooftop air handling unit schedule |
Sprinkler head schedule |
General sprinkler system data |
Sprinkler calculation cover sheet |
Sprinkler hydraulic calculations |
Sprinkler design criteria |
Flow test data |
Pipe and fitting summary |
Sprinkler summary |
Hydraulic design information |
Seismic bracing calculations |
Calculation sheet – NFPA 13d |
|
Sprinkler symbols legend |
Fire protection symbols |
General symbols |
Reference symbols |
Riser designations |
Fire protection symbols |
Fire protection legend |
Sprinkler symbols |
Abbreviations |
Sprinkler system notes |
Limited area sprinkler system notes |
Underground water service piping specification |
Sprinkler note |
Equipment list |
Fire protection notes |
Fire protection - scope of work |
Dry sprinkler system notes |
Sprinkler system notes |
General notes |
|
|
If you have questions about this CAD Details package feel free to call us for more information.